Insulation Resistance Tester
Description
The Fluke 1507 Insulation Tester is compact, rugged, reliable, and easy to use. With it's multiple test voltages, it is ideal for many troubleshooting, commissioning, and preventative maintenance applications. Additional features, like the remote probe on these tools save both time and money when performing tests.
Features
- Automatic calculation of Polarization Index and Dielectric Absorption Ratio saves both time and money
- Compare (Pass/Fail) function - makes repetitive tests simple and easy
- Repetitive or hard-to-reach testing is easy with the remote test probe
- Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
- Auto-discharge of capacitive voltage for added user protection
- Auto Power Off saves battery power
- Large, backlit display allows the user to read measurements easily
- CAT IV 600 V overvoltage category rating for added user protection
- Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
- Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
Includes
- TL224 Test Leads
- TP74 Test Probes
- Alligator Clips PN 1958654 (red) and PN 1958646 (black)
- Holster
- Remote Probe
Warranty
One (1) year
Product Specifications | ||
AC/DC Voltage Measurement | ||
Accuracy | Range | 600.0 V |
Resolution | 0.1 V | |
50 Hz to 400 Hz ± (% of Rdg + Digits) | ± (2 % + 3) | |
Input impedance | 3 MΩ (nominal), < 100 pF | |
Common mode rejection ratio (1 kΩ unbalanced): | > 60 dB at dc, 50 or 60 Hz | |
Overload Protection | 600 V rms or dc | |
Earth bond resistance measurement | ||
Range/Resolution | 20.00 Ω | 0.01 Ω |
200.0 Ω | 0.1 Ω | |
2000 Ω | 1.0 Ω | |
20.00 kΩ | 0.01 kΩ | |
Accuracy | ± (1.5 % + 3) | |
Overload Protection | 2 V rms or dc | |
Open Circuit Test Voltage | > 4.0 V, < 8 V | |
Short circuit current | > 200.0 mA | |
Insulation specifications | ||
Measurement Range | 1507:00:00 | 0.01 MΩ to 10 GΩ |
1503:00:00 | 0.01 MΩ to 2000 MΩ | |
Test voltage | 1507:00:00 | 50 V, 100 V, 250 V, 500 V, 1000 V |
1503:00:00 | 500 V, 1000V | |
Test Voltage Accuracy | + 20 %, - 0 % | |
Short circuit current | 1 mA nominal | |
Auto Discharge | Discharge time < 0.5 second for C = 1 µF or less | |
Live circuit indicator | Inhibit test if terminal voltage > 30 V prior to initialization of test | |
Maximum Capacitive Load | Operable with up to 1 µF load | |
Measure Accuracy: | 50 V: | ±(3 % + 5) |
100 V: | ±(3 % + 5) | |
250 V: | ±(1.5 % + 5) | |
500 V: | ±(1.5 % + 5) | |
1000 V: | ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ | |
General Specifications | ||
Maximum voltage applied to any terminal: | 600 V ac rms or dc | |
Storage Temperature | -40 °C to 60 °C (-40 °F to 140 °F) | |
Operating Temperature | -20 °C to 55 °C (-4 °F to 131 °F) | |
Temperature Coefficient | 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) | |
Relative Humidity | 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) | |
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) | ||
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) | ||
Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | |
Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) | |
Electromagnetic compatibility: | In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) | |
Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) | |
Certifications: | CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition | |
Batteries | Four AA batteries (NEDA 15A or IEC LR6) | |
Battery Life | Insulation test use: | Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
Resistance measurements: | Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. | |
Size | 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) | |
Weight | 550 g (1.2 lb) | |
IP Rating | IP40 | |
Altitude | Operating: | 2000 m CAT IV 600 V, 3000 m CAT III 600 V |
Non-operating (storage): | 12,000 m | |
Over-range capability: | 110 % of range |