Insulation Resistance Tester


Item Number: FLU1587    Supplier: FLUKE ELECTRONICS CORPORATION

Description

The Fluke 1587 Insulation Multimeter combines a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.

Whether you work on motors, generators, cables, or switch gear, the Fluke 1587 Insulation Multimeter is ideally suited to help you with your tasks and at a cost that is far less than buying the two products.

Features

  • Auto discharge of capacitive voltage
  • Insulation test smoothing reading
  • Low pass filter (for work on VSD's)
  • Auto Power Off to save battery power
  • True-rms
  • Large display with backlight
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work

Includes:

  • Remote Probe
  • Test Leads
  • Alligator Clips
  • K-Type Thermocouple
  • Rigged Utility Hard Case
  • Four AA Alkaline Batteries
  • Quick Reference Guide
  • CD Rom with Manual

Warranty

Three (3) years

Product Specifications
Voltage DC
Maximum Voltage:  1000 V
  Accuracy:  ±(0.09%+2)
  Maximum Resolution:  0.001V
Voltage AC Maximum Voltage:  1000 V
  Acurracy:  ±(2%+3)
  AC Bandwidth: 5kHz (with low pass filter; 3db @ 800 Hz)
  Maximum Resolution:  0.1 mV
Current DC Maximum Amps:  400mA
  Amps Accuracy:   1587: ±(0.2%+2)
  Maximum Resolution:  0.01 mA
Current AC Maximum Amps:  400mA
  Amps Accuracy:   ±(1.5%+2) (1kHz bandwidth)
  Maximum Resolution:  0.01 mA
Resistance Maximum Resistance:  50 MΩ
  Acurracy:  ±(0.9%+2)
  Maximum Resolution:  0.1Ω
Capacitance Maximum Capacitance:  9,999 µF
  Accuracy:  ±(1.2%+2)
  Maximum Resolution:  1 nF
Frequency  Maximum Frequency:  100 kHz
  Accuracy:  ±(0.1%+1)
  Maximum Resolution:  0.01 Hz
Temperature Measurement    -40.0 °C to 537 °C
     -40.0 °F to 998 °F
     excluding probe
Diode Test  Range:  6 V
  Resolution:  1 mV
  Accuracy:  ±(2 % + 1)
Insulation Test    
Minimum Test Current @ 1kΩ/V    1mA
Test Voltages    50, 100, 250, 500, 1000 V
Maximum Resistance per Test  50V:  
Voltage 100V:  
  250V:  
  500V:  
  1000V:  1587: 2 GΩ
Maximum Resolution per Test  50V:  0.01 MΩ
Voltage 100V:  0.01 MΩ
  250V:  0.1 MΩ
  500V:  0.1 MΩ
  1000V:  0.1 MΩ
Accuracy per Test Voltage 50V:  ±(3 % + 5)
  100V:  ±(3 % + 5)
  250V:  ±(1.5 % + 5)
  500V:  1587: ±(1.5 % + 5)
  1000V:  1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ
Environmental Specifications    
Operating temperature    –20 °C to +55 °C
Storage temperature    -40°C to +60°C
Humidity (Without     0% - 95% (10 °C – 30 °C)
Condensation)    0% - 75% (30 °C – 40 °C)
     0% - 40% (40 °C – 55 °C)
Operating Altitude    2000 m
Safety Specifications    
Overvoltage category   Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency Approvals   2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical & General Specifications  
Size    203 x 100 x 50 mm (with holster)
Weight    624 g
Battery life Alkaline Meter use: 1000 hours
  Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating    IP40