Notice: Authorized Dealers please log in thru your Internal Dealer Network via TIS:   More Info

Click on: TIS > DIAGNOSTICS > TOOLS & EQUIPMENT > APPROVED DEALER EQUIPMENT WEBSITE
product product Item shown may not be actual product.
Product and price information are subject to change without notice.
Discontinued

Automotive Oscilloscope, TMS Branded


Item Number: PIOPR277    Supplier: PICO TECHNOLOGY

Description

A PicoScope (sometimes known as a labscope) turns your laptop or desktop PC into a powerful diagnostic tool. Think of it as the X-ray machine of diagnostics, letting you see the changing signals inside wires. You can purchase a PicoScope on its own, but most people purchase one of our award-winning Automotive Diagnostics Kits. These money-saving kits contain everything you need – just add a PC.

Warranty

Five years

Specifications

Oscilloscope specifications (vertical)
Bandwidth 20 MHz (10 MHz on ±50 mV range)
Channels 4
Vertical resolution 12 bits
Enhanced vertical resolution 16 bits
DC accuracy ±1% of full scale
Input Sensitivity 10 mV/div to 40 V/div
Input ranges (full scale) ±50 mV to ±200 V in 12 ranges
Input characteristics 1 MΩ in parallel with 24 pF
Input type Floating single-ended BNC connector
Input coupling Software selectable AC/DC
Overvoltage protection ±2500 V (DC + AC peak)
Oscilloscope — horizontal
Maximum sampling rate  
1 channel in use 400 MS/s
2 channels in use 200 MS/s
3 or 4 channels in use 100 MS/s
Maximum sampling rate (USB streaming) 20 MS/s (USB 3.0)
10 MS/s (USB 2.0)
Buffer memory 250 M samples
Waveform buffer Up to 10,000 waveforms
Timebase ranges 100 ns/div to 5000 s/div
Dynamic performance (typical)
Crosstalk 4000:1, DC to 20 MHz
Harmonic distortion < −60 dB
SFDR > 60 dB
Noise 220 μV RMS on 50 mV range
Bandwidth flatness DC to full bandwidth (+0.25 dB, −3 dB)
ADC ENOB 10.8 bits
Triggers
Source Any input channel
Basic triggers Auto, repeat, single, none
Advanced triggers Rising edge, falling edge, edge with hysteresis, pulse width, runt pulse, dropout, windowed
Maximum pre-trigger delay Up to 100% of capture length
Maximum post-trigger delay Up to 4 billion samples
Spectrum analyzer  
Frequency range DC to 20 MHz
Display modes Magnitude, average, peak hold
Windowing functions Rectangular, Gaussian, triangular, Blackman, Blackman-Harris, Hamming, Hann, flat-top
Number of FFT points Selectable from 128 up to 1 million in powers of 2
Scale / units X axis : linear or log 10
Y axis : logarithmic (dbV, dBu, dBm, arbitrary) or linear (volts)
Math channels
General functions −x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, derivative, integral, delay
Filter functions Low pass, high pass, band stop, band pass
Graphing functions Frequency, duty cycle
Multi-waveform functions Min, max, average, peak
Operands Input channel, reference waveforms, time, constants, pi
Automatic measurements
Scope mode AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak to peak, rise time, rising rate.
Spectrum mode Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD+N, SFDR, SINAD, SNR, IMD
Statistics Minimum, maximum, average and standard deviation
Serial decoding
Protocols CAN, LIN, I²C, UART/RS-232, SPI, I²S, FlexRay
Inputs All input channels with any mixture of protocols
Mask limit testing
Mask generation Auto generate from captured waveform, manual drawing, manual coordinate entry
Actions Highlight on screen, select in buffer overview, activate alarm
Statistics Pass/fail, failure count, total count
Alarms
Initiating events Capture, buffer full, mask fail
Alarm actions Beep, play sound, stop/restart capture, run executable, save current buffer/all buffers, trigger signal generator
Data export
Output file formats BMP, CSV, GIF, JPG, MATLAB 4, PDF, PNG, PicoScope data, PicoScope settings, TXT
Output functions Copy to clipboard, print
Environmental
Operating environment  
Temperature range 0 °C to 40 °C (15 °C to 30 °C for quoted accuracy)
Humidity 5% to 80% RH, non-condensing
Storage environment  
Temperature range –20 to +60°C
Humidity 5% to 95% RH, non–condensing
Physical dimensions
Dimensions 190 x 160 x 40 mm (approx 7.5 x 6.3 x 1.6 in)
Weight < 900 g (approx 2 lb)
Software
Software included PicoScope 6 oscilloscope software with waveform database and guided tests. PicoDiagnostics software
Languages Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean*, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish
General
Additional hardware (supplied) USB cable, user manuals, software CD-ROM
PC requirements Desktop or laptop running Windows 7, 8 or 10 recommended
PC connectivity Powered from PC USB port (USB 3.0 / 3.1 recommended, USB 2.0 compatible).
Power requirements Powered from USB ports
Safety approvals LVD compliant
EMC approvals Tested to meet EN61326-1:2006 and FCC Part 15 Subpart B
Environmental approvals RoHS and WEEE compliant